FLX-3232 Installation Guide
Installation Instructions
Shelf Mounting Instructions
Attach the supplied rubber feet to the bottom of the FLX-3232 matrix. Follow the instructions in
General I/O Card Installation to install the I/O cards.
Rack Mounting Instructions
The FLX-3232 requires three rack units (5 RU) of space. At least 2 inches of free air space is
required on both sides of the FLX-3232 for proper side ventilation. Avoid mounting the FLX-3232
near a power amplifier or any other source of significant heat. It is recommended that you leave
an empty rack space above and below the FLX-3232 for additional cooling.
General I/O Card Installation
1. Power off the matrix.
2. Remove the metal blank.
12